The SONOLINE G20™ ultrasound system quickly distances itself from the competition with next-generation all-digital system architecture that utilizes Siemens technology migration. Individual imaging parameters have been optimized for a wide variety of clinical applications and patient types. So you can realize a higher degree of diagnostic confidence.
• All-digital signal processing technology creates excellent image quality
• State-of-the-art beamforming provides a wide acoustic aperture, improved image resolution, uniformity and penetration for difficult-to-image patients…
The SONOLINE G20™ ultrasound system quickly distances itself from the competition with next-generation all-digital system architecture that utilizes Siemens technology migration. Individual imaging parameters have been optimized for a wide variety of clinical applications and patient types. So you can realize a higher degree of diagnostic confidence.
• All-digital signal processing technology creates excellent image quality
• State-of-the-art beamforming provides a wide acoustic aperture, improved image resolution, uniformity and penetration for difficult-to-image patients
• All-digital G20 system architecture enables seamless integration of advanced capabilities including DICOM connectivity solutions, Tissue Harmonic Imaging (THI) and TGO™ tissue grayscale optimization technology
• Ongoing performance enhancements, which require only simple, cost-effective software upgrades, protect your initial investment into the future
The SONOLINE G20 ultrasound system goes beyond excellent image quality to meet your clinical needs. The G20 system incorporates superb workflow advancements, usermatched ergonomics and proven Siemens reliability. The results are efficiency, time savings and greater patient throughput. Without interruption.
• Slim, lightweight design with small footprint and four swivel wheels makes the system ideally suited for use in tight workspaces and easily maneuverable from suite to suite and patient to patient
• Intuitive interface with the familiar Windows®-based operating system promotes efficient and ergonomic system control via on-screen menus and proprietary ReadySet™ workflow shortcuts
• QuickSet™ user programmable system parameters and integrated cine review streamline exams and enhance workflow
• DIMAQ-IP integrated workstation with built-in CD-R/W drive allows quick and easy digital acquisition, storage, review, quantification and transfer of complete ultrasound studies
• TGO technology for instantaneous, one-button image optimization
• Ergonomically designed transducers incorporate lightweight microCase™ transducer miniaturization technology to promote user comfort
• Embedded connectivity solutions allow simple integration into DICOM-enabled networks and PC-based workstations
Physical Characteristics
• Height: 128.3 cm (50.5 inch)
• Width: 46.4 cm ( 18.3 inch)
• Depth: 67.5 cm (26.6 inch)
• Weight: 60 kg (132 pounds) without OEM’s
User Interface
• User-centric control panel with homebase layout
• Intuitive Windows®-based operating principles
• ReadySet™ on-screen workflow shortcuts for instant access to most frequently used functions, without the need to divert your attention from the imaging screen
• On/Off tasklight and back-lit illumination of control panel
• On Screen Menu (OSM) provides easy and immediate access to secondary imaging controls
• Wrist support to help reduce operator repetitive stressdisorders
• Alphanumeric keyboard for standard text, function keys and system programming
• Up to 32 user-definable QuickSet™ user-programmable system parameters for individual tra nsducer/application settings. QuickSets combine all preferred imaging mode parameters, annotation text and measurements into one user preset
• Configurable two-pedal footswitch
Monitor
• Monochrome, 12-inch, high resolution, progressive scan (non-interlaced) CRT
• 640 x 480 pixel display matrix with a recordable image area of 640 x 480 pixels (VGA)
Hard Drive
• Internal 40 GB Hard Drive for patient database management
• Allows storage of patient studies that include images, reports and measurements
• Image storage capacity up to 42,000 black/white images
CD-RW Drive
• Support either 650 MB or 700 MB read/write CD-R
• Allows storage and archiving of complete patient studies including still images, reports and measurements
• Storage capacity dependent upon patient study size
• Export of images in TIFF format, DICOM exchange Media (optional)
Transducer Ports
• Two universal transducer ports that support curved array and linear array
• Electronic transducer selection (instantaneous switching between transducers)
• Industrial design provides easy access to the transducer ports
Transducer Storage
• Four configurable transducer holders support all transducer designs and provide gel bottle storage
• Ergonomic cable management and secure cable management for protection during exams and transport
• Special transducer holder for endocavity transducers provides easy access and storage
Operating/Display Modes
• 2D imaging in fundamental and harmonic modes
• Tissue M-mode
• Flexible combination of imaging modes in side-by-side Dual and Dual Select in real-time and digital cine replay
• Selectable split screen display formats in 2D with M-mode: top-bottom or side-by-side in real-time and digital cine replay
2D Calipers – Generic Measurements and Calculations
• Up to eight distance measurements per screen
• Multiple cursor sets on frozen and cine playback images
• Up to 15 follicle measurements each for right and left side
• Automatic depth measurement from skin line
• Trace length measurement
• Angle measurement
• Area and circumference: ellipse, trace, cross, spine
• Compound Measurements: - Volume: user-selectable calculated by 2-Plane 3
distances, 2-Plane ellipse, 2-Plane trace, 1 Plane 2 distances, 1-Plane ellipse or 1-Plane disk measurements
Cine Review
Cine feature is standard and offers post-acquisition optimization of all real-time post-processing functions.
• Frame-by-frame cine loop review and continuous cine motion review, including control of playback rate
• Independent cine review in mixed modes (2D/M)
• Independent cine review in 2D Dual Select mode with image align playback feature
• Standard Cine Memory: providing up to 64 2D mode images and 32 2B mode frames
• Up to 60 seconds M-mode Cine
• Cine Store: Multiple single frame storage with clipboard review allowing post processing, measurement and annotation functions
Post Processing Features in Freeze Frame or Cine
• 2D-mode
- Zoom/pan
- Gray map
- Measurements/reports/annotations/pictograms
• M-mode
- Gray map
- Measurements/reports/annotations/pictograms
Transducer Technology
Ultra-sensitive, wideband transducers, matched with user-selectable MultiHertz™ multiple frequency imaging, improve resolution and penetration. Depending on the
transducer, the user can select up to five 2D and THI frequencies expanding the clinical versatility of a single transducer, and thereby maximizing transducer
investment.
• Wideband MultiHertz imaging allows user selection of 2D frequencies for optimal resolution and penetration
• microCase™ transducer miniaturization technology combined with SuppleFlex™ transducer cables provide compact, lightweight, comfortable transducers, designed
to help reduce operator fatigue during prolonged scanning sessions
• Universal, stainless steel and disposable biopsy guides for specified linear and curved array transducers
• Innovative ultra low-loss lens materials and microelectronic technologies for efficient performance and increased signal bandwidth
• Frequency range: 2.0 – 10.0 MHz