Sonoline G50 System
View Complete SpecificationsQuick Specs!
The G50 system is a complete all-digital technology platform. It offers the power of individuality, allowing you to choose the customized imaging solution that fits your needs. Productivity tools such as the DIMAQ-IP integrated workstation with embedded DICOM connectivity, stress echo capability and innovative features like SieScape™ panoramic imaging can all be integrated seamlessly.
In addition to excellent imaging performance and a high level of standard features, the G50 system is unique in its individual scalability. Depending on your clinical needs, you can…
The G50 system is a complete all-digital technology platform. It offers the power of individuality, allowing you to choose the customized imaging solution that fits your needs. Productivity tools such as the DIMAQ-IP integrated workstation with embedded DICOM connectivity, stress echo capability and innovative features like SieScape™ panoramic imaging can all be integrated seamlessly.
In addition to excellent imaging performance and a high level of standard features, the G50 system is unique in its individual scalability. Depending on your clinical needs, you can add individual features including additional array and sector transducer port options and an echocardiography package. The system can be customized with additional clinical and workflow functionality migrated from other Siemens ultrasound systems.
Siemens designed the G50 system with your workflow needs in mind. It supports confident decision making with exceptional image quality, highly intuitive operating principles and a classically comfortable user interface.
The newest advanced feature available on the G50 system is fourSight 4D ultrasound imaging technology:
- Automated volume data acquisition in 4D mode that is fully integrated in the clinician's daily workflow
- Simultaneous display of 2D image and 4D volumes give real-time feedback during acquisition
- The C6F3 4D transducer is ergonomically designed for exceptional user and patient comfort
- Cost effective output to CD of 3D volumes and clips
- EV8F5 4D transducer for excellent 2D, 3D and 4D imaging of early gestations and gynecological exams
- Measurement tools for distance and area in 3D MPR images and 3D rendered volume images
Physical Characteristics
• System Height: 142.2 cm (56.0 inch)
• Width: 51.0 cm (20.1 inch)
• Depth: 79.8 cm (31.4 inch)
• Weight: 130 kg (286 pounds) without OEM’s
User Interface
• User-centric control panel with homebase layout
• Windows® based operating principles and on-screen icons to activate most frequently used functions
• Adjustable control panel back-lit illumination
• Function key active state brightening
• Digital Liquid Crystal Display (LCD) provides easy and immediate access to secondary imaging controls
• Wrist support to help reduce operator repetitive
stress disorders
• Retractable alphanumeric keyboard with overhead illumination for standard text, function keys and system programming
• Up to 32 QuickSet™ user programmable system parameters for individual transducer/application settings. QuickSet parameters combine all preferred imaging mode parameters, annotation text and measurements into one user preset
• Programmable two-pedal footswitch
Monitor
• Multi-Sync, 15-inch, high resolution, progressive scan (non-interlaced)
• 800 x 600 pixel display matrix with a recordable image area of 800 x 600 pixels (SVGA)
Hard Drive (with DIMAQ-IP option only)
• Internal 40 GB Hard Drive for patient database management
• Allows storage of complete patient studies including images, dynamic clips, reports and measurements
• Image storage capacity up to 42,000 images; color or black/white, or storage of approximately 6,300 dynamic clips
CD-RW Drive (with DIMAQ-IP option only)
• Removable 650 MB read/write CD-R
Audio Speakers
Transducer Ports
• Two universal array transducer ports that support Curved Array, Linear Array and Phased Array* (*requires cardiac imaging option)
• Optional additional array transducer port
• Optional sector transducer port
• Electronic transducer selection
• Industrial design provides easy access to all transducer ports
Operating/Display Modes
• 2D imaging in fundamental and harmonic modes
• Tissue and color M-mode
• B/W SieScape panoramic imaging (option)
• fourSight 4D imaging (option)
• Color Doppler Velocity mode
• Power Doppler mode
• Directional Power Doppler mode
• PW Pulsed Wave spectral Doppler mode
• Steerable Continuous Wave spectral Doppler mode (with cardiac imaging option only)
• Duplex mode
• Triplex mode
• ECG trace in all modes (with cardiac imaging option only)
• Flexible combination of imaging modes in side-by-side Dual and Dual Select in real-time, and digital cine replay
• Selectable split screen display formats in 2D/color with M-mode and/or spectral Doppler mode: top-bottom or side-by-side in real-time and digital cine replay
2D Calipers – Generic Measurements and Calculations
• Multiple cursor sets on frozen and cine playback images
• Up to eight distance measurements per screen
• Distance, depth from skin line
• Trace Length measurement
• Angle measurement
• Area and circumference: ellipse, trace, cross, spline
• Compound Measurements:
– Volume: user-selectable calculated by 2-Plane 3 distances, 2-Plane ellipse, 2-Plane trace, 1-Plane 2 distances, 1-Plane ellipse or 1-Plane disk measurements
– Flow volume: Combined velocity and distance, or velocity and ellipse measurements
– Stenosis: user-selectable, calculated by area, or diameter measurements
Cine Review
Cine feature offers post-acquisition optimization of all real-time post-processing functions.
• Frame-by-frame cine loop review and continuous cine motion review, including control of playback rate
• Independent cine review in mixed modes (2D/M, 2D/Doppler, 2D/C/Doppler)
• Independent cine review in 2D Dual Select mode with image align playback feature
• Standard Cine Memory: providing up to 255 2D-mode images or up to 255 2D/C images
• Up to 30 seconds Doppler Cine, or up to 30 seconds M-mode Cine
• Cine Store: Multiple single frame storage with clipboardreview allowing post processing, measurement and annotation functions
Post Processing Features in Freeze Frame or Cine
• 2D-mode
- Zoom/pan
- Gray map
- 2D-mode colorization map
- Measurements/reports/annotations/pictograms
• Color
- Zoom/pan
- Color map
- Color invert
- Measurements/reports/annotations/pictograms
• Doppler
- Gray map
- Doppler colorization map
- Angle correct
- Measurements/reports/annotations/pictograms
• M-mode
- Gray map
- M-mode colorization map
- Measurements/reports/annotations/pictograms
Transducer Technology
Ultra-sensitive, wideband transducers, matched with userselectable MultiHertz multiple-frequency imaging, improve penetration and resolution.Depending on the transducer, the user can select up to five 2D and THI frequencies and two color and spectral Doppler frequencies, expanding the clinical versatility of a single
transducer, and thereby maximizing transducer investment.
• Wideband MultiHertz imaging allows user selection of independent 2D and color frequencies for optimal resolution and penetration
• microCase™ transducer miniaturization technology combined with SuppleFlex™ transducer cables provide small, lightweight, comfortable transducers, designed to help reduce operator fatigue during prolonged scanning sessions
• Universal, stainless steel and disposable biopsy guides for specified linear and curved array transducers
• Innovative ultra low-loss lens materials and microelectronic technologies for efficient performance and increased signal bandwidth
• Frequency range: 2.0 – 13.0 MHz