Home  Cardiology Equipment  Stress Test Systems  GE / Marquette Series 2000 Treadmill

GE / Marquette Series 2000 Treadmill

GE / Marquette Series 2000 Treadmill
Item #none
AvailabilityContact us for availability.
Please call for a price.
This item is Refurbished.
Send Page to FriendPrint this page

View Complete SpecificationsQuick Specs!

Series 2000 Treadmill
"Unmatched Performance, Safety and Value"


• Versatile performance allows use on a wider range of patients, up to 450 lbs. and speeds from 0 to 13.5 mph.
• Unmatched safety 60 inch walking surface, standard emergency stop switch, 0 mph start speed, full handrail configuration complies with AHA Guidelines.
• Unmatched reliability with less moving parts and simpler design.
Less maintenance required with a digital controller that negates the need for frequent speed and grade calibrations.


Performance Specifications…

Series 2000 Treadmill
"Unmatched Performance, Safety and Value"


• Versatile performance allows use on a wider range of patients, up to 450 lbs. and speeds from 0 to 13.5 mph.
• Unmatched safety 60 inch walking surface, standard emergency stop switch, 0 mph start speed, full handrail configuration complies with AHA Guidelines.
• Unmatched reliability with less moving parts and simpler design.
Less maintenance required with a digital controller that negates the need for frequent speed and grade calibrations.


Performance Specifications

Maximum Rated Load: 182 kg (450 lbs.)
Drive Motor: 3.0 HP, brushless, DC motor
Elevation Motor: 0.13 HP
Belt Speed Range: 0.0 to 22.5 km/hr (0 to 13.5 mph) at 60 Hz, continuously variable, zero mph start-up
Belt Speed Acceleration/Deceleration: Approximately 0.8 km/sec (0.5 mph/sec)
Elevation Range: 0.0 to 25.0% grade, continuously variable
Elevation Range Increase/Decrease: 1.14%/sec
Manual Treadmill Controller (Optional): Functions: On, Off, Up, Down, Fast, Slow, Automatic Protocol Selection, Elapsed Time, Distance Traveled
Automatic Protocols: 15 exercise and 15 rehabilitation (includes Bruce, Naughton, Balke II, Ellestad, Low Performance)
Maximum Leakage Current: 100 µA, chassis to ground
Interface: RS-232 service port, 9600 baud (VT 100 or equivalent)
RS-422 serial port, 9600 baud (CASE 12/15, MAX-1, MAC VU, and CENTRA Stress Systems)

Physical Specifications

Weight: 181.4 kg (400 lb)
Walking Area: 45.7 cm x 152.4 cm (18 in x 60 in)
Floor Space Required: 73.7 cm x 195.6 cm (29 in x 77 in)
Walking Surface Height: 14.0 cm (5.5 in)
Handrail Height Above Walking Surface: Front: 101.6 cm (40 in)
Side: Maximum 88.9 cm (35 in) descending at 5° angle to 81.3 cm (32 in)

Power/Environmental Specifications

Power Requirements: 200 to 240 VAC, 60 Hz, single phase, 20 A, NEMA 6-20 R wall socket (dedicated circuit recommended)
Power Consumption: 1540 watts
Operating Conditions:
Ambient temperature: 10°C to 35°C (50°F to 95°F)
Relative humidity: 20% to 90%
Storage Conditions:
Temperature range: -18°C to 49°C (0°F to 120°F)
Relative humidity: 20% to 90%

View Complete Specifications